🏨 Hotel GPON Network - Custom Floor Distribution (188 Rooms)

2
OLT Module
3
1:64 Splitters
188
ONUs / Rooms
94
AP Devices
5
Hotel Floors
5
UPS Systems
Televes OLT512EVO
GPON Optical Line Terminal
Hotel Network Core
2.5G Down / 1.25G Up
188 Room Connectivity

Optical 1:64 Splitters (5 units)

Split-01
Floor 4-8
Rooms 1-188
Floor 4 - Hotel Rooms 1-39
39 ONUs | 20 AP Access Points
Room Numbers: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10... through 39
UPC-F4
2000VA UPS
Floor 4 Power

ONUs (39 units) - Individual Room Connectivity

01
Room 1
02
Room 2
03
Room 3
04
Room 4
05
Room 5
06
Room 6
07
Room 7
08
Room 8
09
Room 9
10
Room 10
... (ONUs 11-39 serving rooms 11-39)

AP Access Points (20 units)

AP-001
WiFi6E
AP-002
WiFi6E
AP-003
WiFi6E
AP-004
WiFi6E
... (AP-005 through AP-020)
Floor 5 - Hotel Rooms 40-77
38 ONUs | 19 AP Access Points
Room Numbers: 40, 41, 42, 43, 44, 45, 46, 47, 48, 49... through 77
UPC-F5
2000VA UPS
Floor 5 Power

ONUs (38 units) - Individual Room Connectivity

40
Room 40
41
Room 41
42
Room 42
43
Room 43
44
Room 44
45
Room 45
46
Room 46
47
Room 47
48
Room 48
49
Room 49
... (ONUs 50-77 serving rooms 50-77)

AP Access Points (19 units)

AP-021
WiFi6E
AP-022
WiFi6E
AP-023
WiFi6E
AP-024
WiFi6E
... (AP-025 through AP-039)
Floor 6 - Hotel Rooms 78-115
38 ONUs | 19 AP Access Points
Room Numbers: 78, 79, 80, 81, 82, 83, 84, 85, 86, 87... through 115
UPC-F6
2000VA UPS
Floor 6 Power

ONUs (38 units) - Individual Room Connectivity

78
Room 78
79
Room 79
80
Room 80
81
Room 81
82
Room 82
83
Room 83
84
Room 84
85
Room 85
86
Room 86
87
Room 87
... (ONUs 88-115 serving rooms 88-115)

AP Access Points (19 units)

AP-040
WiFi6E
AP-041
WiFi6E
AP-042
WiFi6E
AP-043
WiFi6E
... (AP-044 through AP-058)
Floor 7 - Hotel Rooms 116-152
37 ONUs | 18 AP Access Points
Room Numbers: 116, 117, 118, 119, 120, 121, 122, 123, 124, 125... through 152
UPC-F7
2000VA UPS
Floor 7 Power

ONUs (37 units) - Individual Room Connectivity

116
Room 116
117
Room 117
118
Room 118
119
Room 119
120
Room 120
121
Room 121
122
Room 122
123
Room 123
124
Room 124
125
Room 125
... (ONUs 126-152 serving rooms 126-152)

AP Access Points (18 units)

AP-059
WiFi6E
AP-060
WiFi6E
AP-061
WiFi6E
AP-062
WiFi6E
... (AP-063 through AP-076)
Floor 8 - Hotel Rooms 153-188
36 ONUs | 18 AP Access Points
Room Numbers: 153, 154, 155, 156, 157, 158, 159, 160, 161, 162... through 188
UPC-F8
2000VA UPS
Floor 8 Power

ONUs (36 units) - Individual Room Connectivity

153
Room 153
154
Room 154
155
Room 155
156
Room 156
157
Room 157
158
Room 158
159
Room 159
160
Room 160
161
Room 161
162
Room 162
... (ONUs 163-188 serving rooms 163-188)

AP Access Points (18 units)

AP-077
WiFi6E
AP-078
WiFi6E
AP-079
WiFi6E
AP-080
WiFi6E
... (AP-081 through AP-094)

Custom Hotel Floor Distribution Summary

Floor 4
39 Rooms (1-39)
20 APs (AP-001 to AP-020)
Floor 5
38 Rooms (40-77)
19 APs (AP-021 to AP-039)
Floor 6
38 Rooms (78-115)
19 APs (AP-040 to AP-058)
Floor 7
37 Rooms (116-152)
18 APs (AP-059 to AP-076)
Floor 8
36 Rooms (153-188)
18 APs (AP-077 to AP-094)
🏨 Custom Distribution: Hotel rooms are distributed as requested: Floor 4 (39 rooms), Floor 5 (38 rooms), Floor 6 (38 rooms), Floor 7 (37 rooms), Floor 8 (36 rooms). Total: 188 rooms with 94 AP access points providing complete coverage.

Exact Hotel Room Distribution